Input (DC) |
DP225U |
DP350U |
Maximum input power (per MPP tracker/total) |
44 / 230 kW |
44 / 360 kW |
Max. input voltage |
1500 VDC |
Operating voltage range |
500 to 1500 VDC |
MPP voltage range |
500 to 1500 VDC |
MPP voltage range with maximum power |
850 to 1350 VDC |
Nominal voltage |
1150 VDC |
Maximum current (per MPP tracker/total) |
40A / 320A |
40A / 480A |
Maximum short-circuit current ISC |
40 A per MPP tracker |
Max. number of MPP-Tracker |
8 |
12 |
Max. number of module strings per MPP tracker |
2 |
String fuses |
not needed |
DC surge protection devices |
Type 2 (EN 50539-11), not replaceable |
Output (AC) |
DP225U |
DP350U |
Maximum apparent power |
225 kVA |
350 kVA |
Maximum active power |
225 kW |
350 kW |
Nominal apparent power |
225 kVA |
350 kVA |
Voltage range |
800 V -20% / +15%; 3 ph. + PE (Y) |
Maximum current |
165 A |
253 A |
Frequency range |
50/60 Hz ± 5 Hz |
Power factor adjustment range |
0.8 kap to 0.8 ind |
Total harmonic distortion (THD) |
< 3% at nominal apparent power |
Consumption in night mode |
< 8 W |
AC surge protection devices |
Typ 2 (EN 61463-11), not replaceable |
General Specifications |
DP225U |
DP350U |
Peak efficiency |
99.0% |
EU efficiency |
98.8% |
Operating temperature range |
-30 to +60 °C |
Temperature range without power derating |
-30 to +50 °C |
Storage temperature range |
-25 to +60 °C |
Relative humidity |
0 to 100%, non-condensing |
Max. operating height |
4000m (above sea level) |
Topology |
Without transformer |
Standard warranty |
5 years (warranty extension available upon request) |
Mechanical Design |
DP225U |
DP350U |
Dimensions (H x W x D) |
765 x 1220 x 397 mm |
925 x 1210 x 370 mm |
Weight |
122 kg |
152 kg |
Cooling |
Replaceable fan module |
Mounting options |
Suspended |
Disconnectors |
3 automatic DC disconnectors |
4 automatic DC disconnectors |
Connection type AC side |
Single raw terminal bolts |
Optional double raw terminal bolts |
Cable specification AC side |
Cu / Al 70 to 300 mm2 |
Cu / Al 120 to 400 mm2 |
Connection type DC side |
Amphenol H4 Pro |
Communication |
DP225U |
DP350U |
Communication interfaces |
2 x RS485, 2 x dry contacts, 1 x external power-off, 6 x digital inputs, Bluetooth®, PLC (PLC100 converter required) |
Data visualization |
DeltaSolar app, MyDeltaSolar Cloud |
Display of operating status |
3 LEDs |
Safety / Standards |
DP225U |
DP350U |
Degree of protection |
IP66 |
Safety class |
I |
Configurable trip parameters |
Yes |
Insulation monitoring |
Yes |
Overload behavior |
Current limit, power limit |
Anti-islanding protection / grid regulation |
EN 50549-1, EN 50549-2, EN 50549-10, VDE-AR-N 4110/4120/4130 |
EMC |
EN 61000-6-2, EN 61000-6-3, EN 61000-3-11, EN 61000-3-12 |
Safety |
IEC 62109-1/-2; CE compliance |