Specifications
- Model
- VX-600VA / VX-1000VA / VX-1500VA
-
- Power Rating
- VX-600VA: 600 VA / 360 W
VX-1000VA: 1000 VA / 600 W
VX-1500VA: 1500 VA / 900 W
-
- Input
- Nominal Voltage: 230 Vac
- Voltage Range: 170~280 Vac
- Frequency Range: 50/60 Hz (Auto sensing)
-
- Output
- Voltage: 230 Vac ± 10% (Battery mode)
- Frequency Range: 50/60 Hz ± 1 Hz
- Waveform (Batt. Mode): Simulated Sinewave
- Receptacle
VX-600VA: IEC 320 C13 x 4
VX-1000VA: IEC 320 C13 x 4
VX-1500VA: IEC 320 C13 x 6
-
- Battery
- Battery Type & Number
VX-600VA: 12V/7AH x 1
VX-1000VA: 12V/7AH x 2
VX-1500VA: 12V/9AH x 2
- Typical Recharge Time: 6~8 hours to 90%
- Cold Start: Yes
-
- Indicator
- LCD: Input voltage, output voltage, battery capacity, load level and UPS status
-
- Interface
Standard: 1 USB port
-
- Environment
- Operating Temperature: 0~40ºC
- Altitude: 0-1000 m
- Relative Humidity: 0~90% RH (Non-condensing)
- Noise Level
VX-600VA: < 40 dB
VX-1000VA: < 40 dB
VX-1500VA: < 45 dB
-
- Conformance
- Safety & EMC: CE
-
- Physical
- VX-600VA
Dimensions (W x D x H): 101 x 300 x 142 mm
Net Weight: 4.4 kg
- VX-1000VA
Dimensions (W x D x H): 130 x 320 x 182 mm
Net Weight: 8.2 kg
- VX-1500VA
Dimensions (W x D x H): 130 x 320 x 182 mm
Net Weight: 10.4 kg
-
- All specifications are subject to change without prior notice.
Management Software Download
ViewPower is an advanced UPS management software for Delta’s VX series UPS. It allows remote monitor and manage from one to multiple UPSs in a networked environment, either LAN or INTERNET. It can not only prevent data loss from power outage and safely shutdown systems, but also store programming data and scheduled shutdown UPSs.
Download the software according to your requested operation system in your computer system from the following link:
www.power-software-download.com/viewpower.html