Products - Ethernet Routers - Delta EMEA

DX-2300LN-WW
Ethernet Cloud Router

Product Introduction

Features & Benefits
  • Data acquisition system connected to cloud servers.
  • Forms a two-way data acquisition channel between a device and the cloud
  • Sets up a secure tunnel between the user and the remote device via the cloud server, without the need for additional VPN servers
  • Supports MODBUS TCP and MODBUS RTU/ASCII protocols
  • Flexible connection options via WAN ports, e.g. static IP, DHCP client and more
  • Range of peripheral interfaces including RS-485, RS-232 and 4 LAN ports
  • Built-in RTC and supports NTP clock synchronization over a network
  • Firewall functions: Stateful Packet Inspection (SPI), Prevent Denial of Service (DoS) attacks, NAT, port triggering, port mapping, IP address filter, MAC address filter, URL filter
  • Supports TCP/IP, UDP, ICMP, DHCP, HTTP, DNS and SSH protocols
  • Job scheduling
  • Import and export of device configurations.
  • Network data flow statistics
  • Network failure diagnostics
  • Device / PLC interlocking
  • Custom alarm conditions with email alerts
  • Supports on-line monitoring via Android and iOS device
Specifications
TECHNOLOGY
Standard Compliance
  • IEEE 802.3 10Base-T
  • IEEE 802.3u 100Base-T(X)
INTERFACE
Fast Ethernet
RJ45 Ports:
  • WAN: 1 10/100Base-T(X), auto MDI/MDI-X, auto negotiation
  • LAN: 4 10/100Base-T(X), auto MDI/MDI-X, auto negotiation
Serial Communication
  • Serial Ports : 1 RS-232(DB9 male), 1 RS-485( Terminal block), 15KV isolation protection
  • Baud Rate: 2400bps to 115200bps
  • Data Bits: 7, 8
  • Parity: None, Even, Odd
  • Stop Bits: 1, 2
  • Flow Control: RTS/CTS(RS-232 only), XON/XOFF
  • RS-232: TxD, RxD, RTS, CTS, GND
  • RS-485: D+, D-, GND
LEDs
  • Device: PWR, SD, Ready
  • RJ45 Ports: 100M, LINK/ACT
  • Serial Ports: RS-232, RS-485
Reset Button
  • 1set
MANAGEMENT
Cloud Service
  • DIACloud
Software
  • SSH, DNS, HTTP, TFTP, DHCP Server/Client, Telnet, Syslog, MODBUS TCP, NTP, MODBUS RTU/ASCII
Security
  • MAC/IP/URL filtering, SSH, SPI, Prevent denial of service (DoS) attacks, Port triggering, Port mapping
Virtual COM Drivers
  • Windows XP, Windows Vista (32/64 bits), Windows 7 (32/64 bits)
Configuration
  • Web Browser, DIACom, Android APP, iOS APP
POWER REQUIREMENTS
  • Input Voltage: 9to 40VDC, 2 pin terminal block input
  • Input Current: 0.53A Max.
  • Overload Current Protection: Present, Max. Input current 1.5A
  • Reverse Polarity Protection: Not Present
PHYSICAL
  • Housing: IP30 metal case
  • Dimensions: 145.3 mm(H) x 45 mm(W) x 112.3 mm (D)
  • Weight: 308g
  • Installation: Industrial DIN-Rail and Wall mounting
ENVIRONMENTAL LIMITS
  • Operating Temperature : -20℃ to 70℃(-4℉ to 158℉)
  • Storage Temperature: -40℃ to 85℃(-40℉ to 185℉)
  • Ambient Relative Humidity: 5% to 95%(non-condensing)
APPROVALS
  • Safety: UL 60950-1, EN 60950-1
  • EMI: FCC 47 CFR Part 15 Subpart B Class A, EN 55022
  • EMS( EN 55024): IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8